Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 369.189
Filter
1.
Arch Oral Biol ; 163: 105980, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38692246

ABSTRACT

OBJECTIVE: To determine the effect of hyaluronic acid (HA) degradation by hyaluronidase (HYAL) in inhibiting collagen fiber production by rat periodontal ligament cells (rPDLCs). DESIGN: Primary rPDLCs were isolated from the euthanized rats and used for in vitro experiments. The appropriate HYAL concentration was determined through CCK-8 testing for cytotoxicity detection and Alizarin red staining for mineralization detection. RT-qPCR and western blot assays were conducted to assess the effect of HYAL, with or without TGF-ß, on generation of collagen fiber constituents and expression of actin alpha 2, smooth muscle (ACTA2) of rPDLCs. RESULTS: Neither cell proliferation nor mineralization were significantly affected by treatment with 4 U/mL HYAL. HYAL (4 U/mL) alone downregulated type I collagen fiber (Col1a1 and Col1a2) and Acta2 mRNA expression; however, ACTA2 and COL1 protein levels were only downregulated by HYAL treatment after TGF-ß induction. CONCLUSIONS: Treatment of rPDLCs with HYAL can inhibit TGF-ß-induced collagen matrix formation and myofibroblast transformation.


Subject(s)
Cell Proliferation , Collagen , Fibroblasts , Hyaluronoglucosaminidase , Myofibroblasts , Periodontal Ligament , Transforming Growth Factor beta , Animals , Periodontal Ligament/cytology , Periodontal Ligament/drug effects , Periodontal Ligament/metabolism , Hyaluronoglucosaminidase/pharmacology , Rats , Myofibroblasts/drug effects , Myofibroblasts/metabolism , Transforming Growth Factor beta/metabolism , Collagen/metabolism , Cell Proliferation/drug effects , Fibroblasts/drug effects , Fibroblasts/metabolism , Hyaluronic Acid/pharmacology , Cells, Cultured , Rats, Sprague-Dawley , Actins/metabolism , Blotting, Western , In Vitro Techniques , Collagen Type I/metabolism , Biomarkers/metabolism , Real-Time Polymerase Chain Reaction , Male , RNA, Messenger/metabolism
2.
BMC Oral Health ; 24(1): 546, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730400

ABSTRACT

BACKGROUND: Recently, a new generation of high-strength flowable dental composites has been introduced by manufacturers. The manufacturers claim that these materials have enhanced mechanical and physical properties and are suitable for use in a wide range of direct anterior and posterior restorations, even in high-stress bearing areas. AIM: The objective of this study was to assess certain physical and mechanical properties of these recently introduced high-strength flowable composites in comparison to conventional multipurpose dental composites. METHODS: Four types of high-strength flowable composites (Genial Universal FLO, Gaenial Universal Injectable, Beautifil Injectable, and Beautifil Flow Plus) were tested in experimental groups, while a nanohybrid conventional composite (Filtek Z350 XT) was used as the control. For flexure properties, ten rectangular samples (2 × 2 × 25 mm) were prepared from each composite material and subjected to 5000 cycles of thermocycling. Samples were then subjected to flexural strength testing using the universal testing machine. Another twenty disc-shaped specimens of dimensions (5 mm diameter × 2 mm thickness) were fabricated from each composite material for surface roughness (Ra) (n = 10) and hardness (VHN) test (n = 10). All samples underwent 5000 cycles of thermocycling before testing. Additionally, microleakage testing was conducted on 60 standardized class V cavities prepared on molar teeth and divided randomly into five groups (n = 12). Cavities were then filled with composite according to the manufacturer's instructions and subjected to thermocycling for 1000 cycles before testing using methylene blue solution and a stereomicroscope. RESULTS: All tested materials were comparable to the control group in terms of flexural strength and surface roughness (p > 0.05), with Gaenial Universal FLO exhibiting significantly higher flexural strength compared to the other flowable composite materials tested. However, all tested materials demonstrated significantly lower elastic modulus and surface hardness than the control group (p < 0.05). The control group exhibited higher microleakage scores, while the lowest scores were observed in the Gaenial Universal FLO material (p < 0.05) CONCLUSION: The physical and mechanical behaviors of the different high-strength flowable composites investigated in this study varied. Some of these materials may serve as suitable alternatives to conventional composites in specific applications, emphasizing the importance of dentists being familiar with material properties before making material selections.


Subject(s)
Composite Resins , Dental Leakage , Flexural Strength , Hardness , Materials Testing , Surface Properties , In Vitro Techniques , Humans , Dental Stress Analysis , Dental Materials/chemistry , Stress, Mechanical , Polyethylene Glycols , Polymethacrylic Acids/chemistry , Bisphenol A-Glycidyl Methacrylate
3.
Am J Dent ; 37(2): 91-100, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38704852

ABSTRACT

PURPOSE: To compare the internal adaptation of restorative systems bonded to mid-coronal and gingival dentin using light-cured, chemical-cured, and dual-cured adhesives, both immediately and after aging. METHODS: 60 molars were selected and received occluso-mesial preparations with dentin gingival margins. Restorations were performed using different restorative systems with light-cured, chemical-cured, and dual-cured adhesives. Internal adaptation was assessed by examining the percentage of continuous margin (%CM) at the pulpal and gingival dentin under a scanning electron microscope at x200 magnification. Half of the teeth were stored in sterile water for 24 hours, while the other half underwent 10,000 thermal cycles. Micro-morphological analysis was conducted on representative samples at x1,000 magnification. RESULTS: The restorative system with light-cured adhesive exhibited significantly lower %CM values at the gingival dentin, particularly after aging. Aging had a negative impact on the %CM values of the pulpal and gingival dentin in restorative systems with light-cured and dual-cured adhesives. Regional dentin variations influenced the %CM values, especially after aging, regardless of the restorative system used. The tested restorative system with chemical-cured adhesive is preferable for achieving improved internal adaptation when bonding to both mid-coronal and gingival dentin, compared to the other tested systems. CLINICAL SIGNIFICANCE: The study highlights the variations in adhesive performance between different regional dentin areas using the tested restorative systems.


Subject(s)
Composite Resins , Gingiva , Humans , Composite Resins/chemistry , Dental Pulp , Dental Restoration, Permanent , Dental Marginal Adaptation , Microscopy, Electron, Scanning , Dentin , Resin Cements/chemistry , Molar , In Vitro Techniques , Light-Curing of Dental Adhesives , Materials Testing
4.
BMC Oral Health ; 24(1): 550, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38734597

ABSTRACT

BACKGROUND: Large cross-arch free-end surgical guides can obscure the visual field, compromising surgical accuracy due to insufficient stability at the free-end. This in vitro study aims to evaluate the accuracy of novel digital non-cross-arch surgical guides designed for implant placement at the mandibular free-end, incorporating tooth undercut retention and screw-bone support. MATERIALS AND METHODS: A mandibular dental model lacking left molars was utilized to fabricate unilateral (cross-arch) tooth-supported surgical guides (GT I, n = 20). Subsequently, two additional types of surgical guides were fabricated: GT II (covering two teeth, n = 20) and GT III (covering three teeth, n = 20). These novel surgical guides were designed to utilize the undercut of the supporting teeth for retention and enhance stability with screw-bone support at the guide's free-end. Furthermore, 60 identical guiding blocks were assembled on the three types of surgical guides to facilitate the implants' insertion. On a phantom head, 120 implant replicas were placed at the Federal Dentaire Internationale (FDI) teeth positions #36 and #37 on the dental model, employing a combination of surgical guides and guiding blocks. To assess accuracy, planned and placed implant positions were compared using intraoral optical scanning. Discrepancies in angulation and linear deviations, including the coronal/apical 3D deviations, lateral deviation as well as depth deviation, were measured. Statistical analysis was performed using two-way ANOVA and Bonferroni test (α = 0.05). RESULTS: GT I exhibited significantly largest discrepancies, including angular and linear deviations at the crest and apex at every implant site. Especially in depth, at implant site #36, the mean deviation value of GT I (0.27 ± 0.13 mm) was twice as large as GT III (0.13 ± 0.07 mm), and almost twice as large as GT II (0.14 ± 0.08 mm). However, at implant site #37, this deviation increased to almost a five-fold relationship between GT I (0.63 ± 0.12 mm) and II (0.14 ± 0.09 mm), as well as between GT I and III (0.13 ± 0.09 mm). No significant discrepancies existed between the novel surgical guides at either implant site #36 or #37. CONCLUSION: This study provides a practical protocol for enhancing accuracy of implant placement and reducing the size of free-end surgical guides used at mandibular molar sites.


Subject(s)
Bone Screws , Mandible , Models, Dental , Surgery, Computer-Assisted , Humans , Mandible/surgery , Surgery, Computer-Assisted/methods , Dental Implantation, Endosseous/methods , Computer-Aided Design , In Vitro Techniques
5.
Clin Oral Investig ; 28(6): 312, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748326

ABSTRACT

OBJECTIVES: Material chemistry and workflow variables associated with the fabrication of dental devices may affect the biocompatibility of the dental devices. The purpose of this study was to compare digital and conventional workflow procedures in the manufacturing of acrylic-based occlusal devices by assessing the cytotoxic potential of leakage products. METHODS: Specimens were manufactured by 3D printing (stereolithography and digital light processing), milling, and autopolymerization. Print specimens were also subjected to different post-curing methods. To assess biocompatibility, a human tongue epithelial cell line was exposed to material-based extracts. Cell viability was measured by MTT assay while Western blot assessed the expression level of selected cytoprotective proteins. RESULTS: Extracts from the Splint 2.0 material printed with DLP technology and post-cured with the Asiga Flash showed the clearest loss of cell viability. The milled and autopolymerized materials also showed a significant reduction in cell viability. However, by storing the autopolymerized material in dH2O for 12 h, no significant viability loss was observed. Increased levels of cytoprotective proteins were seen in cells exposed to extracts from the print materials and the autopolymerized material. Similarly to the effect on viability loss, storing the autopolymerized material in dH2O for 12 h reduced this effect. CONCLUSIONS/CLINICAL RELEVANCE: Based on the biocompatibility assessments, clinical outcomes of acrylic-based occlusal device materials may be affected by the choice of manufacturing technique and workflow procedures.


Subject(s)
Biocompatible Materials , Cell Survival , Materials Testing , Printing, Three-Dimensional , Humans , Biocompatible Materials/chemistry , In Vitro Techniques , Acrylic Resins/chemistry , Cell Line , Blotting, Western
6.
BMC Oral Health ; 24(1): 554, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735924

ABSTRACT

This in vitro study compared various obturation techniques with bioceramic sealers for filling C-shaped 3D-printed replicas. A mandibular molar with a C-shaped root canal with a C1 configuration was obtained. After instrumenting with M3 Pro Gold files (United Dental, Shanghai, China) up to size #30/0.04, a CBCT scan of the tooth was taken. Sixty 3D-printed replicas of the tooth were created. The samples were obturated with EndoSeal TCS sealer (E. TCS; Maruchi, Wonju, Korea) or EndoSeal MTA (E. MTA; Maruchi, Wonju, Korea) (n = 30). The samples in each group were obturated with the following techniques (n = 10): (1) single-cone technique (SC), (2) SC with ultrasonic activation (UA), and (3) cold hydraulic compaction (CHC). Following incubation, the replicas' apical, middle, and coronal thirds were inspected under a digital microscope, and the proportion of filling material and void were calculated. Also, the obturation time and sealer extrusion were recorded. Data were analyzed using ANOVA, LSD post-hoc, and the chi-square tests (α = 0.05). The results indicated that in the apical third, E. TCS-SC, E. TCS-UA, and E. MTA-UA had the lowest void percentage among groups (p < 0.05). In the middle thirds, samples obturated with E. TCS-UA showed a significantly lower void percentage among all groups (p < 0.05). However, in the coronal third, E. TCS-CHC showed the least void percentage (p < 0.05), followed by E. TCS-UA and E. MTA-CHC. The E. TCS-SC and E. TCS-UA were the least time-consuming methods (p < 0.05). Sealer extrusion significantly differed among the groups, with E. MTA-UA and E. TCS-UA showing higher incidence (p = 0.019). It was concluded that E. TCS-UA was the most convenient obturation technique. However, care must be taken when obturating the canals with high flow and ultrasonic activation near the vital anatomical landmarks.


Subject(s)
Printing, Three-Dimensional , Root Canal Filling Materials , Root Canal Obturation , Root Canal Obturation/methods , Humans , Drug Combinations , Molar/diagnostic imaging , In Vitro Techniques , Calcium Compounds , Oxides , Dental Pulp Cavity/diagnostic imaging , Aluminum Compounds , Cone-Beam Computed Tomography/methods , Silicates
7.
BMC Oral Health ; 24(1): 555, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735948

ABSTRACT

OBJECTIVE: This study aimed to evaluate the effect of fence tray matching care (FTMC) in bracket bonding by measuring excess adhesive, as well as linear and angular deviations, and by comparing it with the half-wrapped tray (HWT). MATERIALS AND METHODS: An intraoral scanner was used to acquire data on the maxillary dental arch of a patient with periodontitis.Furthermore, 20 maxillary dental arch models were 3D printed. Using 3Shape, PlastyCAD software, and 3D printing technology, 10 FTMC (method I) and HWT (method II) were obtained. By preoperative preparation, intraoperative coordination, and postoperative measurement, the brackets were transferred from the trays to the 3D-printed maxillary dental arch models. Additionally, the bracket's excess adhesive as well as linear and angular deviations were measured, and the differences between the two methods were analyzed. RESULTS: Excess adhesive was observed in both methods, with FTMC showing less adhesive (P< 0.001), with a statistical difference. Furthermore, HWT's vertical, tip and torque, which was significantly greater than FTMC (P< 0.05), with no statistical difference among other respects. The study data of incisors, canines, and premolars, showed that the premolars had more adhesive residue and were more likely to have linear and angular deviations. CONCLUSIONS: The FTMC had higher bracket bonding effect in comparison to HWT, and the adhesive residue, linear and angular deviations are smaller. The fence tray offers an intuitive view of the precise bonding of the bracket, and can remove excess adhesive to prevent white spot lesions via care, providing a different bonding method for clinical applications.


Subject(s)
Dental Bonding , Orthodontic Brackets , Humans , Dental Bonding/methods , In Vitro Techniques , Models, Dental , Adhesives , Printing, Three-Dimensional , Dental Cements , Dental Arch
8.
J Orthop Surg Res ; 19(1): 280, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711149

ABSTRACT

INTRODUCTION: The escalating incidence of anterior cruciate ligament (ACL) injuries, particularly among adolescents, is a pressing concern. The study of ACL biomechanics in this demographic presents challenges due to the scarcity of cadaveric specimens. This research endeavors to validate the adolescent porcine stifle joint as a fitting model for ACL studies. METHODS: We conducted experiments on 30 fresh porcine stifle knee joints. (Breed: Yorkshire, Weight: avg 90 lbs, Age Range: 2-4 months). They were stored at - 22 °C and a subsequent 24-h thaw at room temperature before being prepared for the experiment. These joints were randomly assigned to three groups. The first group served as a control and underwent only the load-to-failure test. The remaining two groups were subjected to 100 cycles, with forces of 300N and 520N, respectively. The load values of 300N and 520N correspond to three and five times the body weight (BW) of our juvenile porcine, respectively. RESULT: The 520N force demonstrated a higher strain than the 300N, indicating a direct correlation between ACL strain and augmented loads. A significant difference in load-to-failure (p = 0.014) was observed between non-cyclically loaded ACLs and those subjected to 100 cycles at 520N. Three of the ten samples in the 520N group failed before completing 100 cycles. The ruptured ACLs from these tests closely resembled adolescent ACL injuries in detachment patterns. ACL stiffness was also measured post-cyclical loading by applying force and pulling the ACL at a rate of 1 mm per sec. Moreover, ACL stiffness measurements decreased from 152.46 N/mm in the control group to 129.42 N/mm after 100 cycles at 300N and a more significant drop to 86.90 N/mm after 100 cycles at 520N. A one-way analysis of variance (ANOVA) and t-test were chosen for statistical analysis. CONCLUSIONS: The porcine stifle joint is an appropriate model for understanding ACL biomechanics in the skeletally immature demographic. The results emphasize the ligament's susceptibility to injury under high-impact loads pertinent to sports activities. The study advocates for further research into different loading scenarios and the protective role of muscle co-activation in ACL injury prevention.


Subject(s)
Anterior Cruciate Ligament , Stifle , Weight-Bearing , Animals , Swine , Anterior Cruciate Ligament/physiology , Anterior Cruciate Ligament/physiopathology , Stifle/physiology , Stifle/physiopathology , Weight-Bearing/physiology , Biomechanical Phenomena , Anterior Cruciate Ligament Injuries/physiopathology , Stress, Mechanical , In Vitro Techniques
9.
Clin Exp Dent Res ; 10(3): e889, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38712390

ABSTRACT

OBJECTIVE: Radiographs are an integral part of detecting proximal caries. The aim of this study was to evaluate the effect of contrast, brightness, noise, sharpness, and γ adjustment of digital intraoral radiographs on the diagnosis of proximal caries. MATERIALS AND METHODS: In this in vitro study, 40 extracted teeth including 20 premolars and 20 molars with enamel lesions (white spot or dentin discoloration seen through the enamel) were mounted together in groups of eight inside the skull. Bitewing radiographic images of each dental group were obtained by a photostimulable phosphor plate sensor with exposure conditions of 8 mA, 70 kV, and 0.2 s. The images were reconstructed by the built-in software and examined by two oral and maxillofacial radiologists in various settings of contrast, brightness, sharpness, noise, and γ. The teeth were then cut mesiodistally and the presence or absence of caries was confirmed by an oral and maxillofacial pathologist using a stereomicroscope. The data were then analyzed using the κ agreement coefficient, sensitivity, specificity, and accuracy (α = .05). RESULTS: Adjustment of brightness and contrast led to higher diagnostic performance with an accuracy of 82.5% and 83.8 (for observers 1 and 2, respectively) and 82.5% (for both observers), respectively. Noise adjustment was the least helpful approach for diagnosis of proximal dental caries among other adjustments, with an accuracy of 78.8% and 77.5% for observers 1 and 2, respectively. CONCLUSION: Brightness and contrast setting was more efficient in improving the diagnostic potential of bitewing radiographs compared to other adjustments.


Subject(s)
Dental Caries , Radiography, Bitewing , Radiography, Dental, Digital , Humans , Dental Caries/diagnostic imaging , Dental Caries/diagnosis , Radiography, Dental, Digital/methods , Radiography, Bitewing/methods , Sensitivity and Specificity , Bicuspid/diagnostic imaging , In Vitro Techniques , Molar/diagnostic imaging , Software , Image Processing, Computer-Assisted/methods
10.
Anim Sci J ; 95(1): e13950, 2024.
Article in English | MEDLINE | ID: mdl-38712489

ABSTRACT

The utilization of polyphenol-modified starch in ruminants has not undergone extensive exploration. This study aimed to investigate the impact of the complex formed between starch and Melastoma candidum D. Don fruit extract on physicochemical properties, phenol release kinetics in various buffers simulating the gastrointestinal tract, methane production, and post-rumen digestibility. The interaction between starch and M. candidum D. Don fruit extract significantly (p < 0.001) increased resistant starch and particle size diameter. The maximum phenolic release from complex between starch and M. candidum D. Don fruit extract, due to gastrointestinal tract-simulated buffers, ranged from 22.96 to 34.60 mg/100 mg tannic acid equivalent. However, rumen and abomasum-simulated buffers released more phenolic content, whereas the intestine-simulated buffer showed higher antioxidant activity (ferric ion-reducing antioxidant power). Furthermore, complex between starch and M. candidum D. Don fruit extract significantly decreased dry matter rumen digestibility (p < 0.001) and maximum methane gas production (p < 0.001).


Subject(s)
Antioxidants , Chemical Phenomena , Digestion , Fermentation , Melastomataceae , Plant Extracts , Rumen , Starch , Rumen/metabolism , Animals , Starch/metabolism , Antioxidants/metabolism , Melastomataceae/chemistry , Melastomataceae/metabolism , Rheology , Methane/metabolism , Fruit/chemistry , In Vitro Techniques , Phenols/metabolism , Phenols/analysis , Particle Size , Polyphenols/metabolism
11.
BMC Oral Health ; 24(1): 538, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715004

ABSTRACT

BACKGROUND: The introduction of auxiliaries such as composite attachment has improved the force delivery of clear aligner (CA) therapy. However, the placement of the attachment may give rise to a flash, defined as excess resin around the attachment which may affect CA force delivery. This in vitro study aims to determine the differences in the force generated by the attachment in the presence or absence of flash in CA. MATERIALS AND METHODS: Tristar Trubalance aligner sheets were used to fabricate the CAs. Thirty-four resin models were 3D printed and 17 each, were bonded with ellipsoidal or rectangular attachments on maxillary right central incisors. Fuji Prescale pressure film was used to measure the force generated by the attachment of CA. The images of colour density produced on the films were processed using a calibrated pressure mapping system utilising image processing techniques and topographical force mapping to quantify the force. The force measurement process was repeated after the flash was removed from the attachment using tungsten-carbide bur on a slow-speed handpiece. RESULTS: The intraclass correlation coefficient showed excellent reliability (ICC = 0.96, 95% CI = 0.92-0.98). The average mean force exerted by ellipsoidal attachments with flash was 8.05 ± 0.16 N, while 8.11 ± 0.18 N was without flash. As for rectangular attachments, the average mean force with flash was 8.48 ± 0.27 N, while 8.53 ± 0.13 N was without flash. Paired t-test revealed no statistically significant difference in the mean force exerted by CA in the presence or absence of flash for both ellipsoidal (p = 0.07) and rectangular attachments (p = 0.41). Rectangular attachments generated statistically significantly (p < 0.001) higher mean force than ellipsoidal attachments for flash and without flash. CONCLUSION: Although rectangular attachment generated a significantly higher force than ellipsoidal attachment, the force generated by both attachments in the presence or absence of flash is similar (p > 0.05).


Subject(s)
Tooth Movement Techniques , Humans , In Vitro Techniques , Tooth Movement Techniques/instrumentation , Dental Stress Analysis , Orthodontic Appliance Design , Composite Resins/chemistry , Printing, Three-Dimensional
12.
Acta Odontol Scand ; 83: 264-272, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38709122

ABSTRACT

PURPOSE: The purpose of the present in vitro study is to investigate and compare the remineralising potential of Moringa Oleifera extract, eggshell, and sodium fluoride varnish on microhardness of artificially demineralised enamel of primary teeth with biomimetic minimally invasive approach following the world paradigm shift towards natural products in paediatric dentistry. MATERIAL AND METHODS: Sample size included 44 primary molars. The mineral content and surface microhardness of all specimens were initially assessed using energy dispersive x-ray examination (EDX) and Vickers microhardness. The specimens were artificially demineralised for 96 h at a temperature of 37°C and then reassessed directly after demineralisation. The demineralised enamel specimens were randomly divided into four groups according to the remineralisation regimen utilised. Group 1: Artificial saliva (control); Group 2: Sodium fluoride varnish; Group 3: Eggshell hydrogel; and Group 4: Moringa Oleifera hydrogel. The specimens were stored for 8 days and then subsequently evaluated using EDX and microhardness assessment by Vickers microhardness test and scanning electron microscope (SEM).  Results: Regarding the microhardness test, there was a significant difference between the Moringa Oleifera group and Eggshell group compared to fluoride varnish (p < 0.05). Regarding EDX analysis, there was a statistically significant difference (p < 0.05) between Moringa Oleifera group and Eggshell group compared to fluoride varnish as the highest values were for Moringa Oleifera and Eggshell. On the other hand, there was no statistically significant difference (p > 0.05) between Moringa Oleifera and Eggshell in both the measurements. CONCLUSION: Moringa Oleifera and Eggshell might be considered as a biomimetic natural material capable of guiding enamel tissue remineralisation in early carious lesion of primary teeth. CLINICAL RELEVANCE: This research demonstrated the capability for early enamel caries to be remineralised using novel materials with a naturally counterpart implicated in biomineralisation as proved to be more effective than traditionally used fluoride varnish in primary teeth.


Subject(s)
Egg Shell , Hydrogels , Moringa oleifera , Sodium Fluoride , Tooth, Deciduous , Sodium Fluoride/administration & dosage , Tooth, Deciduous/drug effects , Egg Shell/chemistry , Humans , Moringa oleifera/chemistry , Tooth Remineralization/methods , Animals , In Vitro Techniques , Fluorides, Topical/administration & dosage , Microscopy, Electron, Scanning , Dental Enamel/drug effects , Hardness/drug effects , Spectrometry, X-Ray Emission , Tooth Demineralization/prevention & control , Tooth Demineralization/drug therapy
13.
Clin Oral Investig ; 28(5): 294, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38698252

ABSTRACT

OBJECTIVES: To compare ultrasonic scaler prototypes based on a planar piezoelectric transducer with different working frequencies featuring a titanium (Ti-20, Ti-28, and Ti-40) or stainless steel (SS-28) instrument, with a commercially available scaler (com-29) in terms of biofilm removal and reformation, dentine surface roughness and adhesion of periodontal fibroblasts. MATERIALS AND METHODS: A periodontal multi-species biofilm was formed on specimens with dentine slices. Thereafter specimens were instrumented with scalers in a periodontal pocket model or left untreated (control). The remaining biofilms were quantified and allowed to reform on instrumented dentine slices. In addition, fibroblasts were seeded for attachment evaluation after 72 h of incubation. Dentine surface roughness was analyzed before and after instrumentation. RESULTS: All tested instruments reduced the colony-forming unit (cfu) counts by about 3 to 4 log10 and the biofilm quantity (each p < 0.01 vs. control), but with no statistically significant difference between the instrumented groups. After 24-hour biofilm reformation, no differences in cfu counts were observed between any groups, but the biofilm quantity was about 50% in all instrumented groups compared to the control. The attachment of fibroblasts on instrumented dentine was significantly higher than on untreated dentine (p < 0.05), with the exception of Ti-20. The dentine surface roughness was not affected by any instrumentation. CONCLUSIONS: The planar piezoelectric scaler prototypes are able to efficiently remove biofilm without dentine surface alterations, regardless of the operating frequency or instrument material. CLINICAL RELEVANCE: Ultrasonic scalers based on a planar piezoelectric transducer might be an alternative to currently available ultrasonic scalers.


Subject(s)
Biofilms , Dental Scaling , Dentin , Fibroblasts , Periodontal Ligament , Surface Properties , Titanium , Humans , Dental Scaling/instrumentation , In Vitro Techniques , Dentin/microbiology , Periodontal Ligament/cytology , Transducers , Cell Adhesion , Stainless Steel , Equipment Design , Ultrasonic Therapy/instrumentation
14.
BMC Oral Health ; 24(1): 530, 2024 May 04.
Article in English | MEDLINE | ID: mdl-38704553

ABSTRACT

OBJECTIVE: Explore the therapeutic mechanism of Coptidis Rhizome (CR) in periodontitis using network pharmacology, and validate it through molecular docking and in vitro experiments. METHODS: Screened potential active components and target genes of CR from TCMSP and Swiss databases. Identified periodontitis-related target genes using GeneCards. Found common target genes using Venny. Conducted GO and KEGG pathway analysis. Performed molecular docking and in vitro experiments using Berberine, the main active component of CR, on lymphocytes from healthy and periodontitis patients. Assessed effects on inflammatory factors using CCK-8, flow cytometry, and ELISA. RESULTS: Fourteen active components and 291 targets of CR were identified. 30 intersecting target genes with periodontitis were found. GO and KEGG analysis revealed oxidative stress response and IL-17 signaling pathway as key mechanisms. Molecular docking showed strong binding of Berberine with ALOX5, AKT1, NOS2, and TNF. In vitro experiments have demonstrated the ability of berberine to inhibit the expression of Th17 + and other immune related cells in LPS stimulated lymphocytes, and reduce the secretion of IL-6, IL-8, and IL-17. CONCLUSION: CR treats periodontitis through a multi-component, multi-target, and multi-pathway approach. Berberine, its key component, acts through the IL-17 signaling pathway to exert anti-inflammatory effects.


Subject(s)
Berberine , Drugs, Chinese Herbal , Molecular Docking Simulation , Network Pharmacology , Periodontitis , Humans , Periodontitis/drug therapy , Drugs, Chinese Herbal/therapeutic use , Drugs, Chinese Herbal/pharmacology , Berberine/pharmacology , Berberine/therapeutic use , Coptis chinensis , Rhizome , Interleukin-17/metabolism , Signal Transduction/drug effects , In Vitro Techniques , Enzyme-Linked Immunosorbent Assay , Flow Cytometry
15.
Arq Bras Cardiol ; 121(4): e20230236, 2024 Apr.
Article in Portuguese, English | MEDLINE | ID: mdl-38695407

ABSTRACT

BACKGROUND: Vascular dysfunction constitutes the etiology of many diseases, such as myocardial infarction and hypertension, with the disruption of redox homeostasis playing a role in the imbalance of the vasomotor control mechanism. Our group previously has shown that thyroid hormones exert protective effects on the aortic tissue of infarcted rats by improving angiogenesis signaling. OBJECTIVE: Investigate the role of triiodothyronine (T3) on vascular response, exploring its effects on isolated aortas and whether there is an involvement of vascular redox mechanisms. METHODS: Isolated aortic rings (intact- and denuded-endothelium) precontracted with phenylephrine were incubated with T3 (10-8, 10-7, 10-6, 10-5, and 10-4 M), and tension was recorded using a force-displacement transducer coupled with an acquisition system. To assess the involvement of oxidative stress, aortic rings were preincubated with T3 and subsequently submitted to an in vitro reactive oxygen species (ROS) generation system. The level of significance adopted in the statistical analysis was 5%. RESULTS: T3 (10-4 M) promoted vasorelaxation of phenylephrine precontracted aortic rings in both intact- and denuded-endothelium conditions. Aortic rings preincubated in the presence of T3 (10-4 M) also showed decreased vasoconstriction elicited by phenylephrine (1 µM) in intact-endothelium preparations. Moreover, T3 (10-4 M) vasorelaxation effect persisted in aortic rings preincubated with NG-nitro-L-arginine methylester (L-NAME, 10 µM), a nonspecific NO synthase (NOS) inhibitor. Finally, T3 (10-4 M) exhibited, in vitro, an antioxidant role by reducing NADPH oxidase activity and increasing SOD activity in the aorta's homogenates. CONCLUSION: T3 exerts dependent- and independent-endothelium vasodilation effects, which may be related to its role in maintaining redox homeostasis.


FUNDAMENTO: A disfunção vascular constitui a etiologia de diversas doenças, incluindo infarto do miocárdio e hipertensão, diante da ruptura da homeostase oxi-redutiva ("redox"), desempenhando um papel no desequilíbrio do mecanismo de controle vasomotor. Nosso grupo demonstrou anteriormente que os hormônios tireoidianos melhoram a sinalização da angiogênese, exercendo efeitos protetores sobre o tecido aórtico de ratos infartados. OBJETIVOS: Investigar o papel da triiodotironina (T3) na resposta vascular, explorando seus efeitos em aortas isoladas e a presença de mecanismos redox vasculares. MÉTODOS: Anéis aórticos isolados (endotélio intacto e desnudado) pré-contraídos com fenilefrina foram incubados com T3 (10-8, 10-7, 10-6, 10-5 e 10-4 M) e a tensão foi registrada usando um transdutor de deslocamento de força acoplado a um sistema de coleta. Para avaliar o envolvimento do estresse oxidativo, os anéis aórticos foram pré-incubados com T3 e posteriormente submetidos a um sistema de geração de espécies reativas de oxigênio (ROS) in vitro. O nível de significância adotado na análise estatística foi de 5%. RESULTADOS: A T3 (10-4 M) promoveu o vasorrelaxamento dos anéis aórticos pré-contraídos com fenilefrina em endotélio intacto e desnudado. Os anéis aórticos pré-incubados na presença de T3 (10-4 M) também mostraram diminuição da vasoconstrição provocada pela fenilefrina (1 µM) em preparações de endotélio intacto. Além disso, o efeito vasorrelaxante da T3 (10-4 M) persistiu em anéis aórticos pré-incubados com éster metílico de NG-nitro-L-arginina (L-NAME, 10 µM), um inibidor inespecífico da NO sintase (NOS). Por fim, a T3 (10-4 M) exibiu, in vitro, um papel antioxidante ao reduzir a atividade da NADPH oxidase e aumentar a atividade da SOD nos homogenatos aórticos. CONCLUSÃO: A T3 exerce efeitos dependentes e independentes de endotélio, o que pode estar relacionado ao seu papel na manutenção da homeostase redox.


Subject(s)
Oxidation-Reduction , Oxidative Stress , Rats, Wistar , Reactive Oxygen Species , Triiodothyronine , Vasodilation , Animals , Vasodilation/drug effects , Vasodilation/physiology , Male , Triiodothyronine/pharmacology , Oxidation-Reduction/drug effects , Reactive Oxygen Species/metabolism , Oxidative Stress/drug effects , Phenylephrine/pharmacology , Endothelium, Vascular/drug effects , Endothelium, Vascular/physiology , Rats , Reproducibility of Results , Vasoconstrictor Agents/pharmacology , Aorta, Thoracic/drug effects , Aorta, Thoracic/physiology , In Vitro Techniques , Vasoconstriction/drug effects , Vasoconstriction/physiology
16.
J Contemp Dent Pract ; 25(3): 231-235, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690695

ABSTRACT

AIM: This study aimed to compare the bond strength of AH Plus sealer to root canal dentin when used with or without various antibiotics including amoxicillin, clindamycin, and triple antibiotic mixture (TAM). MATERIALS AND METHODS: A total of 80 single-rooted extracted human teeth were instrumented and obturated with gutta-percha and four different sealer-antibiotic combinations (n = 20). Group I: AH Plus without any antibiotics, Group II: AH Plus with amoxicillin, Group III: AH Plus with clindamycin, and Group IV: AH Plus with TAM. After seven days, the roots were sectioned perpendicular to their long axis and 1 mm thick slices were obtained from the midroots. The specimens were subjected to a push-out bond strength test and failure modes were also evaluated. Data was analyzed using Kruskal-Wallis and Dunn's post hoc tests. RESULTS: Group IV had significantly higher bond strength compared to other groups (p ≤ 0.05). No significant differences were found between other groups. While the sealer-antibiotic groups predominantly showed cohesive failure modes, the control group displayed both cohesive and mixed failure modes. CONCLUSION: Within the limitations of this study, the addition of TAM increased the push-out bond strength of AH Plus. CLINICAL SIGNIFICANCE: Amoxicillin, clindamycin, or TAM can be added to AH Plus for increased antibacterial efficacy without concern about their effects on the bond strength of the sealer. How to cite this article: Adl A, Shojaei NS, Ranjbar N. The Effect of Adding Various Antibiotics on the Push-out Bond Strength of a Resin-based Sealer: An In Vitro Study. J Contemp Dent Pract 2024;25(3):231-235.


Subject(s)
Amoxicillin , Anti-Bacterial Agents , Dental Bonding , Epoxy Resins , Root Canal Filling Materials , Humans , Root Canal Filling Materials/chemistry , In Vitro Techniques , Clindamycin , Materials Testing , Dental Stress Analysis , Root Canal Obturation/methods
17.
J Contemp Dent Pract ; 25(3): 245-249, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690698

ABSTRACT

AIM: The aim of the study is to determine the difference in the shear bond strengths to dentin among dental composite (Filtek Z350®, 3M), compomer (Dyract Flow®, Dentsply) and Giomer (Beautifil®, Shofu) with 3MTM Single BondTM Universal Adhesive (SBU) (7th generation, self-etch, single solution adhesive) and AdperTM Single Bond 2 Adhesive (ASB) (5th generation, total-etch, two solution adhesive). MATERIALS AND METHODS: Sixty extracted human permanent teeth were collected, cleansed of debris, and placed in distilled water. The samples were segregated into two groups depicting the two bonding agents-AdperTM (ASB) and 3MTM Single Bond Universal (SBU) and sub-grouped into three groups depicting the three restorative materials (Composite, Giomer, and Compomer) used. Groups were respresented as follows: Group I-ASB + Composite; Group II-ASB + Giomer; Group III-ASB + Compomer; Group IV-SBU + Giomer; Group V-SBU + Compomer; Group VI-SBU + Composite. After applying the bonding agent as per the manufacturer's instructions, following which the restorative material was placed. A Universal Testing Machine (Instron 3366, UK) was employed to estimate the shear bond strength of the individual restorative material and shear bond strengths were calculated. RESULTS: Composite bonded with SBU (group VI) displayed the greatest shear strength (11.16 ± 4.22 MPa). Moreover, Giomers and flowable compomers displayed better bond strengths with ASB compared with their SBU-bonded counterparts. CONCLUSION: These results mark the importance of careful material selection in clinical practice and the bonding agent used to achieve optimal bond strength and enhance the clinical longevity and durability of dental restorations. CLINICAL SIGNIFICANCE: From a clinical perspective, to avoid a compressive or a shear failure, it would be preferrable to use a direct composite restorative material with SBU (Single bond universal adhesive, 7th generation) to achieve maximum bond strength. How to cite this article: Kuchibhotla N, Sathyamoorthy H, Balakrishnan S, et al. Effect of Bonding Agents on the Shear Bond Strength of Tooth-colored Restorative Materials to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):245-249.


Subject(s)
Compomers , Composite Resins , Dental Bonding , Dental Stress Analysis , Dentin-Bonding Agents , Dentin , Shear Strength , Composite Resins/chemistry , Humans , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , In Vitro Techniques , Compomers/chemistry , Bisphenol A-Glycidyl Methacrylate , Dental Restoration, Permanent/methods , Materials Testing , Glass Ionomer Cements/chemistry , Dental Materials/chemistry , Acrylic Resins/chemistry
18.
J Contemp Dent Pract ; 25(3): 250-259, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690699

ABSTRACT

AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Filling Materials , Root Canal Obturation , Root Canal Preparation , Tomography, Spiral Computed , Tooth, Deciduous , Humans , Root Canal Obturation/methods , Tooth, Deciduous/diagnostic imaging , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Tomography, Spiral Computed/methods , Molar/diagnostic imaging , Dental Instruments , In Vitro Techniques
19.
J Contemp Dent Pract ; 25(3): 221-225, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690693

ABSTRACT

AIM: This study aimed to assess the color stability of bioactive restorative materials vs nanohybrid resin composites after 3 months of immersion in three frequently consumed beverages. MATERIALS AND METHODS: Thirty disk-shaped specimens of Giomer dental restorative material (Shofu, Japan) and nanohybrid resin composite (Tokuyama, Japan) were performed using a Teflon mold. Super-Snap system (Shofu, Japan) was utilized to finish and polish the specimens to be preserved for 24 hours in distilled water at 37°C. The samples had been divided into three subgroups (Coffee, tea, Pepsi) (n = 5). The initially displayed color measurements of the samples were performed using a spectrophotometer (VITA Easyshade® V). After 7 days, 30 days, and 90 days, color measurements were repeated, and the E of each sample was estimated. E of each sample was calculated. RESULTS: The Giomer group showed statistically significant higher E values than the nanohybrid resin composite where the p-value was ≤0.0001. Tea subgroup showed the highest statistically significant E values in both groups where the p-value was ≤ 0.0001. The highest statistically significant color change was recorded at 3 months. CONCLUSION: The color of bioactive restorative material is less stable if compared with nanohybrid resin composite. CLINICAL SIGNIFICANCE: As tea and coffee are popular beverages, particularly in Middle Eastern nations, dentists must advise patients about the color change of resin restorations. Patients are advised to brush their teeth immediately after consuming these beverages. How to cite this article: Saber EH, Abielhassan MH, Abed YA, et al. Color Stability of Bioactive Restorative Material vs Nanohybrid Resin Composite: An In Vitro Study. J Contemp Dent Pract 2024;25(3):221-225.


Subject(s)
Color , Composite Resins , Materials Testing , Tea , Composite Resins/chemistry , In Vitro Techniques , Coffee , Spectrophotometry , Dental Restoration, Permanent , Nanocomposites/chemistry , Dental Materials/chemistry , Humans , Beverages
20.
J Contemp Dent Pract ; 25(3): 226-230, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690694

ABSTRACT

AIM: To assess the effectiveness of various surface treatments and adhesives on the bond strength of zirconia-based ceramic to dentin. MATERIALS AND METHODS: Eighty samples of zirconia were subjected to the four-surface treatment protocols (sandblasting, 48% hydrofluoric acid (HF), 48% hydrofluoric acid + 70% nitric acid (HNO3) and no treatment (control) following which the samples from each group were subdivided into two subgroups (n = 10) based on the resin cement employed for cementation (RelyX U200 and G-Cem Linkforce). The bonded specimens were subjected to shear stress to measure the bond strength using Universal testing machine. To test the difference in bond strength among the eight study groups, the Kruskal-Wallis ANOVA test was applied and for comparison between cements in each group, Mann-Whitney U test was applied. RESULTS: The highest bond strength values were observed for 48% HF group cemented with G-Cem Linkforce resin cement (16.220 ± 1.574) and lowest for control group-RelyX (4.954 ± 0.972). G-Cem cement showed higher bond strength than RelyX for all surface treatments except 48% HF + 70% nitric acid. CONCLUSION: It can be inferred that 48% HF can etch zirconia and generate a porous structure that proves to be beneficial for bonding. CLINICAL SIGNIFICANCE: The increasing demand for esthetics has led to the replacement of metal-ceramic materials with zirconia-based ceramics. However, the chemical inertness of zirconia to various conventional surface treating agents has continuously challenged researchers to discover a new surface treatment protocol that could enhance the bond strength of zirconia. How to cite this article: Yenamandra MS, Joseph A, Singh P, et al. Effect of Various Surface Treatments of Zirconia on its Adhesive Properties to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):226-230.


Subject(s)
Dental Bonding , Dentin , Materials Testing , Resin Cements , Surface Properties , Zirconium , Resin Cements/chemistry , Dental Bonding/methods , In Vitro Techniques , Humans , Dental Stress Analysis , Shear Strength , Hydrofluoric Acid/chemistry , Nitric Acid/chemistry , Ceramics/chemistry
SELECTION OF CITATIONS